Aptagen, LLC
            
                
                     DNA
            
            Myoglobin
            
            Protein
            
            4.93 nM (reported value)
            
            20 mM Hepes, 120 mM NaCl, 5 mM KCl, 1 mM CaCl2, 1mM  MgCl2, pH 7.3
            
            23°C
            
            
                                    NA If the oligo is a known aptamer sequence: For binding studies, perform a refolding protocol to ensure proper function (i.e. binding to antigen or target). Refer to the aptamer reference source for the appropriate refolding parameters and binding conditions. Note: it is unknown whether aptamer functions properly without refolding.
                
                            
            
            DNA
            
            Myoglobin
            
            Protein
            
            4.93 nM (reported value)
            
            20 mM Hepes, 120 mM NaCl, 5 mM KCl, 1 mM CaCl2, 1mM  MgCl2, pH 7.3
            
            23°C
            
            
                                    NA If the oligo is a known aptamer sequence: For binding studies, perform a refolding protocol to ensure proper function (i.e. binding to antigen or target). Refer to the aptamer reference source for the appropriate refolding parameters and binding conditions. Note: it is unknown whether aptamer functions properly without refolding.             
            
            
            
            
            
        
    Myo40-7-27 (ID# 602)
 
                
                
                5'dCpdCpdCpdTpdCpdCpdTpdTpdTpdCpdCpdTpdTpdCpdGpdApdCpdGpdTpdApdGpdApdTpdCpdTpdGpdCpdTpdGpdCpdGpdTpdTpdGpdTpdTpdCpdCpdGpdAp3'
                
                
                40
                                    
                    12131.88 g/mole
                
                                    
                    350000 L/(mole·cm)
                
                                    
                    55.00%
                    
                    2.86
                    
                    34.66
                
                
                    
                
                
            
        Note: Information on this aptamer oligo was obtained from the literature and hasn't been validated by Aptagen.
Wang, Q., et al. ƒ??Sensitive point-of-care monitoring of cardiac biomarker myoglobin using aptamer and ubiquitous person glucose meter.ƒ? Biosensors and Bioelecgtronics, 64 (2015): 161-164. Wang, Q., et al. ƒ??Screening of DNA Aptamers against Myoglobin Using a Positive and Negative Selection Units Integrated Microfluid Chip and its Biosensing Application.ƒ? Analytical Chemistry, 86 (2014): 6572-6579.
Have your aptamer oligo synthesized ORDER NOW



 
                
We are always looking for ways to improve. Please tell us what you think.